POLARIS C
TURBINE WATER METER
SINGLE-JET DRY DIAL
STRAIGHT READING 8 ROLLERS |
|

DN 15 |
NEW DN 20 |
CEE 75/33 |
2004/22/CE - M I D - |
Cold water |
30 ° C |
Cold water |
T 30 |
Typical Sensitivity |
4,5 lh |
Typical Sensitivity |
6,5 lh |
Max flow rate - Qmax |
3.000 lh |
Max flow rate - Q4 |
5.000 lh |
Nominal flow rate - Qn |
1.500 lh |
Nominal flow rate - Q3 |
4.000 lh |
transizional flow rate - Qt |
22,5 lh |
transizional flow rate - Q2 |
40,0 lh |
Min flow rate - Qmin |
15 lh |
Min flow rate - Q1 |
25 lh |
Max working pressure |
16 Bar |
Max working pressure |
16 Bar |
Metrological class |
C - H |
Metrological class |
R 160 |
Max reading dial |
99.999 m³ |
Max reading dial |
99.999 m³ |

|
360° ROTATING DIAL
OPTIONS
- Wiper against internal condensation
- Special version equipped with modularis pulser device
- Anti magnetic tamper device
- Unions
- Chromed brass casing
- Protection ring and lid
|
|
DIMENSIONS
Calibre
|
D
(mm) |
L
(mm) |
H
(mm) |
H1
(mm) |
H2
(mm) |
DN15
(1/2")
|
3/4" |
110 |
69 |
78 |
143 |
3/4" (7/8"-3/4") |
115 |
69 |
78 |
143 |
DN20
(3/4") |
1" |
130 |
72 |
81 |
146 |
|
|
|
 |
|
 |
|