PEGASUS
TURBINE WATER METER
MULTI-JET PROTECTED ROLLERS |
|

*For short periods the temperature can reach 50° C
Working pressure 16 bar
SIZE
CALIBRE |
Nominal flow rate
Qn
|
Max flow rate
Qmax
|
Transition flow rate
transizione
Qt |
Min flow rate
Qmin |
Starting flow rate |
Min
reading |
Max
reading |
Max temp.
|
mm |
inches |
m3/h |
m3/h |
l/h |
l/h |
l/h |
l |
m3 |
°C |
13/15 |
1/2” |
1,5 |
3 |
22,5 |
15 |
3,5 |
0,05 |
99.999 |
30° |
20 |
3/4” |
2,5 |
5 |
37,5 |
25 |
5 |
0,05 |
99.999 |
30° |
25 |
1” |
3,5 |
7 |
52,5 |
35 |
10 |
0,05 |
99.999 |
30° |
30 |
1”1/4 |
5 |
10 |
75 |
50 |
10 |
0,05 |
99.999 |
30° |
40 |
1”1/2 |
10 |
20 |
150 |
100 |
20 |
0,05 |
999.999 |
30° |
50 |
2” |
15 |
30 |
225 |
90 |
20 |
0,05 |
999.999 |
30° |
MAX PRESSURE LOSS DIAGRAM
TYPICAL ERROR CURVE

Special versions equipped with pulses device
|

Full mechanical drive up to the totalizer
|
DIMENSIONS
Size Calibre
|
mm |
13/15 |
20 |
25 |
30 |
40 |
50 |
inches |
1/2” |
3/4” |
1” |
1”1/4 |
1”1/2 |
2” |
| L mm |
110
130-145
160-165
170 |
160
190 |
|
160
220
260 |
200
300 |
300 |
| H mm |
105 |
105 |
120 |
120 |
130 |
140 |
| A mm |
35 |
35 |
40 |
40 |
60 |
70 |
| B mm |
96 |
96 |
100 |
100 |
136 |
136 |
| D inches |
3/4” |
1” |
1”1/4 |
1”1/2 |
2” |
2”1/2 |
* Size 50 mm available also with flanges ISO PN10/16 |
|
|
 |
|
 |
|